Skip to content
DT Nova
Services

Fire protection inspection software for alarm, sprinkler and extinguisher companies

Fire protection inspection software that plans every system at every site on the frequency its rules require, records each detector, sprinkler valve and extinguisher on site, turns every failure into a deficiency and a quote, and produces the inspection report the building owner, the authority and the insurer accept. We build custom fire alarm inspection software and fire sprinkler inspection software for fire protection contractors, hosted in the EU, and your company owns the code.

  • You see the result before it goes live
  • Fixed price for the agreed scope, in writing before work starts
  • Source code, domain and accounts in your company's name

Request a quote

Why fire protection companies need more than a scheduler

Our field service management software page covers companies with technicians on the road in general. Fire protection is inspection-led in a way few trades are. Most of the work is recurring tests on fixed frequencies, many of them monthly, quarterly, semiannual and annual on the same site. The unit of work is the device: a building may have hundreds of detectors, dozens of extinguishers and several sprinkler risers, and the report has to account for each. And the report itself is the product: it is what proves to the authority having jurisdiction, the insurer and the building owner that the system works.

Many companies still collect results on paper or in spreadsheets, type them into report templates at the office, and track deficiencies in a separate list that nobody turns into quotes on time.

What the system does

Inspection frequencies and records

Inspection rules come from national law and from standards adopted by reference. In the United States, OSHA requires portable fire extinguishers to be visually inspected monthly and subjected to an annual maintenance check, with the annual maintenance date recorded and the record kept for one year after the last entry or the life of the shell, whichever is less. Stored pressure dry chemical extinguishers that require a 12-year hydrostatic test must be emptied and maintained every 6 years, and the employer must keep evidence of hydrostatic testing as a certification record with the date, the signature of the person who performed the test and the serial number or other identifier (29 CFR 1910.157(e) and (f)). Fire alarm, sprinkler and extinguisher work follows NFPA 72, NFPA 25 and NFPA 10 where they are adopted, with frequencies set per component.

In England and Wales, the responsible person must ensure that the premises and the facilities, equipment and devices provided for fire safety are subject to a suitable system of maintenance and are maintained in an efficient state, in efficient working order and in good repair (Regulatory Reform (Fire Safety) Order 2005, article 17). Other European countries set their own national inspection rules, usually built on EN series standards for detection, sprinklers and extinguishers. (Sources read on 12 November 2026; the NFPA and EN standards are named, not quoted.)

The system does not hard-code one rulebook. Each system type carries the tasks and frequencies from the standards and editions you work to, approved by your technical lead before go-live. Each site is assigned the rule set that applies to it, the next inspections are planned from the last ones, and when an edition changes, the change is made once and applied to every affected site.

Fire alarm inspection software, device by device

A fire alarm inspection is a list of devices to test. The system imports the device list from the panel export or the commissioning documents, with address, type, zone and location. On site, the technician works through the list in the app, marking each device as passed, failed or not accessible, and the panel's event log can be imported where the panel allows it, so the test time of each device is recorded. The app shows what is left on each floor, so a device behind a locked door does not disappear from the report. Over the year, partial inspections rotate through the devices so every one is tested at the required frequency, and the report proves it.

Fire sprinkler inspection software

Sprinkler systems are inspected by component: control valves, gauges, alarm devices, fire pumps, backflow preventers, heads and the water supply, each on its own frequency. The system stores each riser and its components, presents the right checklist for the visit, records readings such as static and residual pressure and pump test results, and flags values outside the limits you set. Long-interval tasks, such as internal pipe inspections, are planned years ahead and do not drop out when a customer changes contact person.

Extinguishers, emergency lighting and fire doors

Extinguisher work is high volume: hundreds of units per site, each with a type, location, manufacture date and service history. Each unit gets a barcode or tag. The technician scans it, records the check and any service, and the system plans internal examinations, recharges and hydrostatic tests from the unit's own dates. Missing or relocated units are flagged on the site map. Emergency lighting tests and fire door inspections use the same model: a list of items per site, a checklist per item, results per item and deficiencies from failures.

Deficiencies that turn into revenue

Every failed device, damaged head, missing extinguisher or door that does not close is a deficiency, and an unquoted deficiency is a risk for the customer and lost work for you. The system records each with its severity, photos and recommended action, and puts it in a queue for quoting. Quotes are built from your price list, sent to the customer's portal for approval, and booked as repair jobs linked to the original finding. Impairments, when a system is taken out of service, are recorded with start and end times and the notifications you require.

Reports for owners, authorities and insurers

Reports are generated from the site data in the formats you need: the forms your authority or insurer accepts, your own branded reports and summaries for building owners with several sites. They list every device tested and its result, the deficiencies found and their status, and the technician and certification number. Customers download them from the portal, and where an authority runs a reporting platform with an interface or upload format, reports can be submitted to it.

The technician app

Technicians see their route and each site's systems, device lists, floor plans, access notes and history. They test device by device, scan extinguishers, record readings and photos, create deficiencies and get a signature. The app works offline in basements, risers and plant rooms and syncs when the signal returns. We build for iPhone and Android from one codebase.

Ready-made fire inspection software or custom?

There are established products for fire protection contractors, such as Inspect Point, ServiceTrade, BuildOps and Uptick. For many companies one of them fits, and we will say so. Custom software pays off when your national rules and report forms, your mix of systems, your device imports or your customers' reporting do not match what the product assumes, or when results are still typed in at the office.

SituationReady-made productCustom software
US work under NFPA, standard formsOften well coveredRarely worth building
European national rules and report formsVaries, often limitedYour country's rules and forms
Device imports from your panel makesSupported formats onlyThe panels you service
Owners with many sites and their own reportingStandard portalThe reports your owners ask for
Data location and ownershipThe vendor's platform and regionYour account, EU data region

How we build it

  1. Workshop with the office and the field. Your service manager, technical lead and senior technicians show how inspections, deficiencies and reports run today. We write the rules down for approval.
  2. Scope and fixed price in writing. Systems, rule sets, report forms, imports and integrations for the first phase, with a fixed price for that agreed scope.
  3. A test version on real data. Your sites, device lists and last quarter's inspections, so reports can be compared with the ones you send today.
  4. Pilot with one team and acceptance. A group of technicians uses the app for a few weeks, checklists and reports are tuned, and the phase is accepted against the written scope.
  5. Roll out and measure. Overdue inspections, time from inspection to report, deficiencies quoted and closed are compared with the numbers recorded at the start.
  6. Maintenance. Updates, monitoring, backups and rule changes when standards change, on a monthly plan you can cancel with one month's notice.

As a standard term, the source code sits in a repository in your company's own account, and the database and hosting are in your name. Companies that also install intruder alarms and cameras can extend the same base with alarm company software; facility teams who manage fire safety among other assets may want facility management software. See prices.

Questions we get

What is fire protection inspection software?

Software for companies that inspect, test and maintain fire alarm systems, sprinkler systems, extinguishers, emergency lighting, fire doors and suppression systems. It plans recurring inspections per site and system, records the result of every device on site, turns failures into deficiencies and quotes, and produces the report the building owner, the authority and the insurer need.

Can it work as fire alarm inspection software device by device?

Yes. Each detector, manual alarm point, sounder, module and panel is a device on the site's list with its address, location and zone. The technician marks each one as tested with its result, the app shows which devices are still untested, and the report lists every device rather than a summary line.

Does it handle extinguisher maintenance and hydrostatic test dates?

Yes. Each extinguisher has its type, location, manufacture date and service history. Monthly checks, annual maintenance and longer-interval internal examinations and hydrostatic tests are planned from the dates and the rules you set, such as those in OSHA 29 CFR 1910.157 in the United States.

Which inspection standards does the software follow?

The ones that apply to your customers. Fire protection work is governed by national law and standards, for example NFPA 10, 25 and 72 in the United States or national standards and EN series in Europe. We build the frequencies, checklists and report forms from the editions you work to, and you approve them before go-live.

Can deficiencies become quotes automatically?

Yes. A failed device or a missing extinguisher becomes a deficiency with severity and photos. The office or the technician turns it into a quote from your price list, the customer approves it in the portal, and the repair is booked and linked to the original finding.

Who owns the software?

Your company. The source code sits in a repository in your own account, and the database and hosting are in your name in an EU data region.

Get a written quote

Tell us in a few lines what you need. We reply within one working day with a written quote: scope, timeline and a fixed price or an hour estimate. Asking is free and commits you to nothing.

See every price · Contact details

Request a quote